My Garage
Cart
Make sure this part fits

Ford F1DZ-10C359-A
Voltage Regulator

1990-2011 Ford F1DZ10C359A

Customer Questions & Expert Answers (24)
Ford F1DZ-10C359-A Voltage Regulator
Ford F1DZ-10C359-A Voltage Regulator
  • Part Description
    Regulator And Brush
  • Base No.
    10C359
  • Replaces
    FODZ-10316-A
  • Manufacturer
    Ford
  • Manufacturer's Notes
    This part is discontinued.
Make sure this part fits
  • Related Parts
  • Product Specifications
  • Vehicle Fitment
  • Customer Questions & Expert Answers
  • Product Specifications

    BrandGenuine Ford
    Base No.10C359
    Manufacturer Part NumberF1DZ-10C359-A
    Part DescriptionRegulator And Brush
    Other NamesBrush & Holder; Regulator Assembly; Brushes; Regulator; Regulator And Brush Holder Assembly
    Item Dimensions3.9 x 2.4 x 2.3 inches
    Item Weight0.40 Pounds
    ConditionNew
    Fitment TypeDirect Replacement
    ReplacesFODZ-10316-A
    ManufacturerFord
    SKUF1DZ-10C359-A
    WarrantyThis genuine Ford part is guaranteed by Ford's factory warranty.
    Shipping & ReturnShipping Policy Return Policy
    Warning: California's Proposition 65
  • Vehicle Fitment

    Year Make Model Trim Engine
    1992-1997 Ford AerostarBase, Eddie Bauer, XL, XL Plus, XL Sport, XLT, XLT Plus, XLT Sport6 Cyl 3.0 L GAS, 6 Cyl 4.0 L GAS
    1993-1996 Ford BroncoCustom, Eddie Bauer, XL, XLT, XLT Lariat, XLT Sport8 Cyl 5.0 L GAS, 8 Cyl 5.8 L GAS
    1995-1997 Ford ContourBase, GL, GL Sport, LX, LX Sport, SE, Sport4 Cyl 2.0 L BI-FUEL, 4 Cyl 2.0 L GAS, 6 Cyl 2.5 L GAS
    1992-1999 Ford Crown VictoriaBase, LX, Police Interceptor, S, Touring Sedan8 Cyl 4.6 L CNG, 8 Cyl 4.6 L GAS
    2003-2004 Ford E-150Base6 Cyl 4.2 L GAS, 8 Cyl 4.6 L GAS, 8 Cyl 5.4 L GAS
    2003-2004 Ford E-150 Club WagonChateau, XL, XLT6 Cyl 4.2 L GAS, 8 Cyl 4.6 L GAS, 8 Cyl 5.4 L GAS
    1992-2002 Ford E-150 EconolineBase, XL6 Cyl 4.2 L GAS, 6 Cyl 4.9 L GAS, 8 Cyl 4.6 L GAS, 8 Cyl 5.0 L GAS, 8 Cyl 5.4 L BI-FUEL, 8 Cyl 5.4 L GAS, 8 Cyl 5.8 L GAS
    1992-2002 Ford E-150 Econoline Club WagonChateau, Custom, XL, XLT6 Cyl 4.2 L GAS, 6 Cyl 4.9 L GAS, 8 Cyl 4.6 L GAS, 8 Cyl 5.0 L GAS, 8 Cyl 5.4 L BI-FUEL, 8 Cyl 5.4 L GAS, 8 Cyl 5.8 L GAS
    2003-2004 Ford E-250Base6 Cyl 4.2 L GAS, 8 Cyl 4.6 L GAS, 8 Cyl 5.4 L CNG, 8 Cyl 5.4 L GAS
    1992-2002 Ford E-250 EconolineBase, XL6 Cyl 4.2 L GAS, 6 Cyl 4.9 L BI-FUEL, 6 Cyl 4.9 L GAS, 8 Cyl 5.4 L BI-FUEL, 8 Cyl 5.4 L CNG, 8 Cyl 5.4 L GAS, 8 Cyl 5.8 L GAS
    View More
  • Customer Questions & Expert Answers

    Q:
    Can you verify if F1DZ-10C359-A is the right one for my car? Posted by FordPartsDeal Specialist
    A:
    Select Your Vehicle model to verify if part number F1DZ-10C359-A fits your car.
    Posted by FordPartsDeal Specialist
    Q:
    How to service the voltage regulator on Ford E-150? Posted by Customer
    A:
    Service of the voltage regulator requires generator removal and subsequent steps of removing the generator brush device and terminal holder before performing work on the regulator. The generator brush and terminal holder must be separated from the voltage regulator through screw cap removal and screw disassembly. After positioning the brush and terminal holder on the voltage regulator please secure it through screws while keeping the screw cap over Test Terminal A to prevent shorting the B+ battery connection. Install the generator brush and terminal holder and voltage regulator while depressing the brushes for insertion with a wire to keep them in position. Place all components correctly while securing screws before taking out the wire. Finally, reinstall the generator.
    Posted by FordPartsDeal Specialist
    Q:
    How to service the voltage regulator on Ford E-250? Posted by Customer
    A:
    Service of the voltage regulator requires generator removal and subsequent steps of removing the generator brush device and terminal holder before performing work on the regulator. The generator brush and terminal holder must be separated from the voltage regulator through screw cap removal and screw disassembly. After positioning the brush and terminal holder on the voltage regulator please secure it through screws while keeping the screw cap over Test Terminal A to prevent shorting the B+ battery connection. Install the generator brush and terminal holder and voltage regulator while depressing the brushes for insertion with a wire to keep them in position. Place all components correctly while securing screws before taking out the wire. Finally, reinstall the generator.
    Posted by FordPartsDeal Specialist
    Q:
    How to service and repair the voltage regulator on Ford E-250 Econoline? Posted by Customer
    A:
    Service and repair operations on the voltage regulator begin with generator removal. Service and repair of the voltage regulator begins by first removing the generator followed by taking out the generator brush and terminal holder by unscrewing their attaching hardware. Drilling the screw cap and screws enables separation of the generator brush from the voltage regulator terminal holder. Start by positioning the brush and terminal holder on the voltage regulator before installing its screws as well as screw cap to ensure Test Terminal A has the screw cap properly sealed due to its role in preventing battery positive (B+) shorting. Depress the generator brushes before you place them with the terminal holder next to the voltage regulator. Then secure the position by inserting a wire for the brushes. Place the components on position while installing screws afterward removing the wire. Finally, reinstall the generator.
    Posted by FordPartsDeal Specialist
    Q:
    How is the generator brush and terminal holder assembly, along with the voltage regulator, serviced and installed on Ford Expedition? Posted by Customer
    A:
    The composite of generator brush and terminal holder and voltage regulator must be installed at once. Maintenance on this assembly starts with disassembly of the generator. The first step requires you to remove the screws from both the generator brush and terminal holder and voltage regulator assembly before gently extracting the complete assembly. Brushes should be compressed when you put the wire inside to maintain their position throughout the installation. The generator brush must be installed along with the terminal holder together with the voltage regulator assembly before securing it using screws followed by taking out the wire supporting the brushes.
    Posted by FordPartsDeal Specialist
    Q:
    How to service and repair the voltage regulator on Ford E-150 Econoline? Posted by Customer
    A:
    The first step to service and repair the voltage regulator involves generator removal using appropriate alternator procedures. You must eliminate the generator brush together with terminal holder and voltage regulator after unscrewing them. The generator brush must be detached from its terminal holder when separating it from the voltage regulator through screw cap removal and loose of screws. The installation process starts by setting up the brush and terminal holder on the voltage regulator but includes screwing in the components while making sure the screw cap covers Test Terminal A because this stops contact between the battery positive (B+) and unintentional shorting. To finish the installation depress the brushes and insert a wire to secure them before installing the generator brush and terminal holder with the voltage regulator. Align all components correctly and fasten screws before eliminating the wire from its position. Finally, reinstall the generator.
    Posted by FordPartsDeal Specialist
    Q:
    How to service and repair the voltage regulator in gasoline-engine generators on Ford Excursion? Posted by Customer
    A:
    The repair process for the voltage regulator begins with generator removal but this procedure only works for gasoline generators because 7.3L diesel engines possess a regulated generator inside their system. Start by removing the four screws that secure the voltage regulator while proceeding to separate both the generator brush and terminal holder. Separating the generator brush and terminal holder from the voltage regulator requires removing the screw cap together with the two screws fastening the brush and terminal holder. The installation process begins with placing the brush and terminal holder onto the voltage regulator then fastening with screws and putting back the screw cap which must cover Test Terminal A so the battery positive connection does not get shorted. Depress the brushes and add a wire for stabilizing them before putting in the generator brush with the terminal holder and voltage regulator set-up. Once the voltage regulator is installed, remove the wire without losing its position and complete the installation. Finally, reinstall the generator.
    Posted by FordPartsDeal Specialist
    Q:
    How to service and repair the voltage regulator on Ford F-150? Posted by Customer
    A:
    The first task for servicing or repairing the voltage regulator involves removing the generator from its location. Start by unfastening all screws that secure the generator brush and terminal holder as well as the voltage regulator assembly. You should start the installation process by pressing down the brushes while installing wires to maintain position for generator brush and terminal holder and voltage regulator assembly assembly. Install the screws afterward but first remove the wire from the secured assembly. Finally, reinstall the generator.
    Posted by FordPartsDeal Specialist
    Q:
    How to service and repair the voltage regulator in gasoline-engine generators on Ford F-250 Super Duty? Posted by Customer
    A:
    You should start by taking off the generator after making note of this repair process's restriction to gas engines since diesel generators have built-in internal regulators which cannot be serviced independently. You must detach the generator brush and terminal holder along with the voltage regulator by removing the four screws on the voltage regulator. To isolate the generator brush and terminal holder from the voltage regulator proceed by unscrewing the screw cap and subsequently removing the two screws attaching the generator brush and terminal holder. Position the brush and terminal holder correctly on the voltage regulator before installing generator brush and terminal holder screws and placing the screw cap making sure it covers Test Terminal A to avoid battery positive connection shorting. Reinstall all pieces by using a wire to compress the brush while you restore the generator brush and terminal holder following the voltage regulator. To finish the installation you must place the generator brush and terminal holder and the voltage regulator while installing its screws afterward you need to remove the wire before reinserting the generator.
    Posted by FordPartsDeal Specialist
    Q:
    How to Address Issues with the Voltage Regulator on a Ford F-150? Posted by Customer
    A:
    Starting service and repair of the voltage regulator involves generator removal first. One should begin by removing the generator brush and terminal holder and voltage regulator assembly through screw removal. Start with brush depression until you can insert a wire to maintain their position while carrying out the installation steps. You need to install the generator brush and terminal holder before securing it with screws along with the voltage regulator assembly. Afterward you should take out the wire. Finally, reinstall the generator.
    Posted by FordPartsDeal Specialist
    Q:
    How to service the voltage regulator on Ford F-150 Heritage? Posted by Customer
    A:
    The service procedure for voltage regulator consists of removing the generator then the generator brush and terminal holder with the voltage regulator assembly using correct screw removal. After inserting the wire to depress the brushes, install the generator brush with terminal holder together with the voltage regulator assembly while fastening with screws before removing the wire. Finally, reinstall the generator.
    Posted by FordPartsDeal Specialist
    Q:
    How should the voltage regulator and brush holder be serviced as a single assembly on Ford Mustang? Posted by Customer
    A:
    Service operations need to be performed on the voltage regulator and brush holder unit together. First remove the generator component followed by taking out the regulator and brush holder by removing their screws. The new generator regulator and brush holder should be installed while pressing down on the brushes before you insert your wire as a holding mechanism. After securing both the regulator and brush holder properly install their screws then remove the positioning wire. Finally, reinstall the generator. Vehicle relearning requires you to drive 16 km (10 miles) or more after disconnecting and reconnecting the battery since the adaptive strategy needs time to complete the relearning process.
    Posted by FordPartsDeal Specialist
    Q:
    How to service and repair the voltage regulator on Ford Ranger? Posted by Customer
    A:
    The first step to work on the voltage regulator involves removing the generator unit. The necessary screws should be unscrewed to remove the generator brush and terminal holder (part A) with the voltage regulator assembly (part B). The first step for installation should be to install the generator brush and terminal holder (part A) and the voltage regulator assembly (part B). Place the brushes (part C) flat against the surface before using part D wires to maintain brush position while installing. To install the generator brush and terminal holder (part A) and voltage regulator assembly (part B) secure first the screws then take away part D which is the wire. Finally, reinstall the generator.
    Posted by FordPartsDeal Specialist
    Q:
    How to service and repair the voltage regulator for gasoline-engine generators on Ford F-350 Super Duty? Posted by Customer
    A:
    The first step for servicing or repairing the gasoline-engine generator voltage regulator requires removal of the generator itself. Unscrew the four voltage regulator screws to remove it together with the terminal holder and generator brush from the device. You need to disconnect the generator brush and terminal holder from the voltage regulator through the removal of its screw cap followed by unscrewing the two screws which stabilize the generator brush and terminal holder. Set the brush and terminal holder on the voltage regulator next then fasten it with both generator brush and terminal holder screws for installation. Test Terminal A requires the attachment of the screw cap to stop any possible short circuit involving the battery positive charge. Press the brushes before inserting a wire for support when installing the generator brush and terminal holder and the voltage regulator. Position the components first and install the voltage regulator screws before removing the wire. Finally, reinstall the generator.
    Posted by FordPartsDeal Specialist
    Q:
    How to service the voltage regulator on Ford Ranger? Posted by Customer
    A:
    The voltage regulator service demands generator removal as the first step. The next procedure requires removal of four screws that hold the generator voltage regulator assembly together with its generator brush and terminal holder. The assembly of the voltage regulator requires tightening the screws to 3 Nm while using 27 lb-in torque measurement. Before generator brush assembly it is critical to insert a wire specifically plastic into the holding wire insertion hole of the brush to keep the generators stacks properly aligned. The correct generator operation requires users to remove the wire just before starting their vehicle. The last step ends the installation process by performing the reverse action of removal.
    Posted by FordPartsDeal Specialist
    Q:
    How to service the voltage regulator on Lincoln Navigator? Posted by Customer
    A:
    Service of the voltage regulator requires generator removal before beginning the work. The first step involves removing generator brushes and terminal holders together with the voltage regulator assembly using screw removal. During installation you should first compress the brushes as you put in a wire that will maintain their position during the procedure. After securing the generator brush together with terminal holder you can place the voltage regulator assembly along with screws before you remove the wire. The installation process ends with generator reinstallation.
    Posted by FordPartsDeal Specialist
    Q:
    What should be done after removing the voltage regulator assembly for the 2001 Ford Escort? Posted by Customer
    A:
    Depress the (A) brushes and insert the (B) wire to hold the brushes in place for installation.
    Posted by FordPartsDeal Specialist
    See expert answers on similar Voltage Regulator
    Q:
    What should be done after removing the generator for the 2000 Ford Escort? Posted by Customer
    A:
    Take out the generator brush terminal holder and the voltage regulator assembly by unscrewing the screws and removing the assembly.
    Posted by FordPartsDeal Specialist
    See expert answers on similar Voltage Regulator
    Q:
    What should be done after removing the generator for the 2002 Ford Escort? Posted by Customer
    A:
    Next, depress the brushes and insert a wire to hold the brushes in place during installation.
    Posted by FordPartsDeal Specialist
    See expert answers on similar Voltage Regulator
    Q:
    What should be done after removing the generator for the 2000 Ford Explorer? Posted by Customer
    A:
    Take out the voltage regulator/brush holder assembly by removing the screws.
    Posted by FordPartsDeal Specialist
    See expert answers on similar Voltage Regulator
    Q:
    What should be removed after the generator for the 2005 Ford Ranger? Posted by Customer
    A:
    Next, take out the generator brush and terminal holder, along with the voltage regulator assembly by unscrewing the necessary screws.
    Posted by FordPartsDeal Specialist
    See expert answers on similar Voltage Regulator
    Q:
    How do you hold the brushes during installation for the 2004 Ford Ranger? Posted by Customer
    A:
    Press the brushes and insert a wire to hold them during the installation process.
    Posted by FordPartsDeal Specialist
    See expert answers on similar Voltage Regulator
    Q:
    How should the installation be completed for the 2008 Ford Ranger? Posted by Customer
    A:
    Reverse the removal procedure.
    Posted by FordPartsDeal Specialist
    See expert answers on similar Voltage Regulator
    Q:
    How do you prepare for the installation of the voltage regulator/brush holder assembly for the 2000 Mercury Mountaineer? Posted by Customer
    A:
    Depress the brushes and insert a wire to hold them in place.
    Posted by FordPartsDeal Specialist
    See expert answers on similar Voltage Regulator
    If you have any questions about this product, please don't hesitate to ask us. We will be happy to help you!

OEM Ford F1DZ-10C359-A, Excellent Performance and Perfect Fitment

To ensure reliability, purchase Ford part # F1DZ-10C359-A Voltage Regulator. It is sometimes referred to as Ford Voltage Regulator. For those Ford owners who aspire to maintain their vehicles in optimal shape, opting for OEM parts is a wise choice. Precisely engineered, these components adhere to stringent factory guidelines and are produced in state-of-the-art facilities using cutting-edge technologies. Moreover, they are subjected to thorough testing to certify their resilience and safety, thereby making them a dependable option for Ford owners.

FordPartsDeal.com is a leading supplier of genuine Ford parts such as Ford F1DZ10C359A Voltage Regulator. A vast selection of genuine Ford parts is available on our website, all offered at discounted prices. Every OEM Ford part is covered by the manufacturer's warranty, which also applies to our hassle-free return policy. Enjoy fast delivery service, ensuring you get your parts when you need them. Your shopping experience here is guaranteed to be pleasurable. For detailed Ford parts information, click here.